SCOP up to 4,7 / SEER up to 9,1
Energy efficiency class up to A++ / A+++
V-Blocking filter
The V-Blocking filter stops 99% of adhering viruses and other harmful substances such as bacteria, mold and allergens. The two-layer filter with non-woven filter fabric and electrostatic filter ensures effective removal of small particles from the air.
PQC (optionally)
The MSZ-EF series units can be optionally equipped with the Plasma Quad-Connect filter. The new plasma filter effectively removes bacteria, viruses, mold, allergens and floating dust.
Quiet operation
Mitsubishi Electric’s advanced Silent Mode fan speed setting ensures super quiet operation of just 19 dB for cooling mode for EF18/22/25 models.
WI-FI as standard
The built-in Wi-Fi module gives you the ability to directly control MSZ-EF series air conditioners using a dedicated app for smartphones and tablets or via a computer.
WiFi MELCloud
The unit can be equipped with a Wi-Fi adapter and controlled remotely via smartphone, tablet or PC using the control software MELCloud.

Wired Remote Control connectable (optional)
The unit can be equipped with a cable remote controller.

I-save
The I SAVE function can be used to save the preferred operating mode. This operating mode can then be accessed by pressing the I-save key.

Silent
Silent mode for particularly low levels of operating noise, e.g. during the night.

ON/OF
The on/off timer can be used to configure fixed switch-on and switch-off times.

Weekly Timer
The weekly timer can configure up to four individual switching points for each day, enabling flexible switch-on and switch-off of the unit. A temperature specification can also be provided for each switching point to ensure demand-oriented and energy-saving control.

Econo Cool
Przyczynia się do oszczędzania energii poprzez automatyczne podniesienie zadanej temperatury o 2 °C w trybie chłodzenia. Zmniejszona moc chłodzenia nie jest odczuwana dzięki specjalnemu programowi wentylatora.

Auto Swing
Ensures the optimum air volume depending on the output requirements. If a high output is required shortly after switchon, the unit automatically switches to a high stage. The air volume is automatically reduced once the desired temperature is reached.

Vertical Swing
The air outlet flap moves up and down, thereby ensuring pleasant distribution of the conditioned air throughout all areas of the room

Standard Filter
Filters coarse dust (>800 µm) from room air and prevents contamination of the heat exchanger.

V-Blocking Filter
The anti-viral V-Blocking filter stops adhering viruses and other harmful substances, such as bacteria, mold and allergens. The two-layer filter with non-woven filter and electrostatic surface ensures filtration of small particles from the air in the room.

Plasma Quad Connect filter
Plasma Quad filter technology ensures highly effective air purification. Plasma ionisation and the electrostatically charged filter ensure that even the smallest particles (PM2.5; <2.5 μm) such as pollen, viruses, mould, bacteria and allergens are separated and rendered harmless.

VRF LEV-Kit
Makes it possible to connect M-series indoor units to City Multi VRF systems. The LEV kit provides the external electronic expansion valve that indoor units need for operation with City Multi VRF systems.

Low-temperature Cooling
The integrated winter regulation enables cooling mode even at low outside temperatures. The outdoor unit fan speed is automatically reduced in order to maintain stable condensation pressure. If the outdoor unit is exposed to strong winds, then a wind protection panel is required.

Low-temperature Heating
The heat pump function enables energy-saving heating of the rooms. High efficiency even at low temperatures leads to low energy consumption, and conventional heating systems can be replaced with heat pumps in many cases.

Auto Restart
When the voltage is restored, the units automatically start up with the previously selected settings. This ensures a high level of operational reliability.

R32 Pre-charged
R32 (difluoromethane [CH2F2]) belongs to the group of HFC refrigerants and has been used as a component of R410A refrigerant for many years. Given its GWP of 675, it already meets the requirements of the F-gas Regulation for the year 2025.

Certified Quality
The German Building Air Conditioning Association (FGK) has bestowed its quality seal for room air conditioning units on the split air conditioning unit

Inverter
The outdoor unit is equipped with energy-saving inverter technology

Reuse Piping
The inverter outdoor unit is equipped as standard with Replace technology, which enables easy reuse of existing R22 and R407C pipes.1
1 See our M-series design documents for information on the compatibility of existing pipe cross-sections with the new units.